Short Description
A commercial lift with a hydraulic drive system, automatic power doors and emergency battery powered lowering. Maximum travel distance is 15 metres with a maximum of 7 stops.
If this lift is to be used in a public building it must comply with the relevant Australian Standard. Contact the supplier for details.
Options
. Egg crate ceilings
. Woodfold or Visifold car gates (residential use only)
. Horizontally collapsible scissor gates (residential use only) - AS1735.16
. Automatic operation (residential use only)
. Telephone box and telephone
. Custom cab sizes
. Plastic and oak laminate panels
. Customwood cab interiors
. Variety of lock types
. Infinity I manual swing doors
. Machine cabinet
. Custom brass control station and trim
. Variety of call station types
Models
. Available in two models Infinity I and Prolift II.
. Infinity II has additional features to Infinity I eg. remote infrared call
buttons. Visual alert with digital display and audio alert upon door
opening / floor arrival.
More Details
STANDARD INFINITY FEATURES:
. Optical scanner floor selector control
. Slack / broken cable safety device
. Anti-creep releveling device
. Emergency battery lowering with automatic recharging system
. Emergency automatic lighting in event of power failure
. Downspeed limit flow control valve
. Emergency stop button in pit
. Upper and lower limit switches
. Compact hydraulic pump unit
STANDARD CAB FEATURES:
. Stainless control panel and trim
. Stainless steel or oak handrail
. Wide selection of standard melamine for cab walls
. Digital floor indicator in car
. Solid ceiling with two pot lights
. "Car In Use" illuminated hall buttons and car buttons
. Automatically timed car lighting
. Skid resistant rubber flooring
LIFT SPECIFICATIONS:
. Power 208 volt 3, phase or 220 volt, single phase, 30 amp
. Drive System 1 to 2 cable hydraulic
. Rated Load Capacity 454 kg
. Rated Speed .15 m/s nominal
. Maximum Travel 15 m
. Number of Stops 7 maximum
. Control System Key controlled constant pressure (AS1735.15)
. Pit Depth Required 205 mm
. Overhead Clearance Required 2440 mm
ENTRANCE FEATURES: Available on Prolift II Model
. 24 hour UL/ULC fire rated entrance assembly
. Swing clear unexposed heavy duty steel hinges
. Automatic power door operator concealed in door frame
. Auto door opener utilises pulse width modulation for accurate and
adjustable speed control and pressure sensitivity
. Variable speed concealed door closer
. Hidden door interlock with no visible beak
. Aluminium push plate, door handle and kick plates
. Integrated call station and digital car position indicator in door frame
. Aluminium checker plate landing sill
. Infrared remote call button and key switch
. Electrically controlled time delay lock for vandal resistant security
. Visual alert with digital display and audio alert upon door opening / floor arrival
Installation
In NSW the owner or controller of the lift (if not the owner) is required to register their lift with WorkCover. They need to complete Form PL2 Application For Item Registration of Lift / Escalator and Moving Walkway. A fee of $65 is charged. The applicant must state that the plant has been inspected by a competent person and is safe to operate (use).
It is recommended that the lift be inspected annually by a competent person. WorkCover requires payment for registration as well as an annual fee.
Request further details from the supplier or contact WorkCover Plant Registration Unit Tel: 02 9370 5221. If outside the Sydney metropolitan area, phone the WorkCover NSW Client Contact Centre on 13 10 50 or the nearest WorkCover Regional Office.
It is an offence to operate plant that is not correctly registered under the Occupational Health and Safety Regulation 2001.
Place Of Manufacture
Concord (USA)
Standards
For some types of equipment, specific Australian Standard(s) are applicable to the materials used in, the manufacturing processes applied to and the installation of products. Compliance with relevant Standards is indicated by written certification that a product has been tested and assessed as compliant with specified Australian Standards. Purchasers are advised to check with the supplier or manufacturer of this item as to its compliance with relevant Australian Standard(s).