Short Description
A traction drive residential vertical lift with a seven person capacity and maximum travel distance of 12 m or six floors. The lift is designed to suit small spaces. It is fully automatically computer controlled with automatic sliding landing and cabin doors. It does not require a machine room. Suitable for new or existing buildings. Customisation options are available.
Options
* Steel and glass shafts
* Unlimited styling options
* Aluminium anodised or stainless steel handrail
* Mirror: full wall, half wall and glass walls
* Range of floors, landing doors, walls, cabin profiles
* Vertical or horizontal controls
* Alternative car sizes
Models
Only one model available
More Details
* Method of lift operation: automatic push buttons with key isolation to the lift cabin
* Method of door operation: automatic opening
* Accessibility of control panel within the lift: wheelchair accessible height option
* 0.30 m/s speed
* Nominal pit and headroom requirements
* Single phase 20 amp power requirement
* The lift is supplied with or without a steel shaft
* Aluminium anodised or stainless steel handrail
* Compliance AS 1735:18 and AS 1735:16
MEC drive system - features:
* No machine cabinet or room (a genuine MRL)
* Traction drive with steel rope and counter weight balancing
* Nominal 2800mm headroom from top floor finished floor level
* 48v DC motor
* A battery supported drive system that enables the Supermec to run during a total power failure (up to about 20 runs)
* Power failure proof technology
* Smooth and silent lift operation
Installation
In NSW the owner or controller of the lift (if not the owner) is required to register their lift with WorkCover. They need to complete Form PL2 Application For Item Registration of Lift / Escalator and Moving Walkway. A fee of $65 is charged for a lift installed in a public place. The applicant must state that the plant has been inspected by a competent person and is safe to operate (use).
It is compulsory that the lift be inspected annually by a competant person. WorkCover requires payment for registration as well as an annual fee.
Request further details from the supplier or contact WorkCover Plant Registration Unit.
It is an offence to operate plant that is not correctly registered under the Occupational Health and Safety Regulation 2001.
Standards
Specific Australian Standards or other Standard(s) may be applicable for materials, manufacturing processes, or installation of some types of equipment. Compliance with relevant Standards is indicated by written certification that a product has been tested and assessed as compliant with specific Standards. Purchasers are advised to check with the supplier or manufacturer of this item as to its compliance with relevant Standard(s).
Code compliance
AS1735 Part 18
BCA E3.6
AS1735 Part 12 (optional)
Place Of Manufacture
Italy