Easy Air 500 Series Lexus Overlay

This alternating air mattress system consists of 17 interchangeable cells with low air loss, CPR and pillow function. The system includes a lightweight electronic air pump. It is designed for the medium to high risk patient. The overlay fits all standard hospital and homecare beds. It stands apart from the 500 series XL Plus model with a more streamlined, ultra lightweight and effective pump.

Learn More 
Features: Alternating Air, Low Air Loss, Water Resistant
  Easy Air Lexus Overlay
Image Gallery:
Call supplier for a price
(1 supplier)

More Details

Structure
* Interchangeable cells for optimum blood flow
* Compact, lightweight and portable

Attachment
* Four easy to attach corner straps

Pump and Controls
* Ultra lightweight pump. Very compact
* Pump designed to suit user weight up to 150 kg
* Extremely quiet
* If there is a leakage or damage in the bed causing loss of a large amount of pressure, the yellow warning light will be lit and an alarm buzzer will be activated to remind the nursing attendant to check the bed and system for problems
* Includes hooks for easy attachment of pump to bed
* Air pressure to weight ratio indicated and outlined on pump face control
* Static function

Cover
Multi stretch vapour permeable cover. A quilted full zip cover.

Safety Features
* Alarm
* Low pressure indicator
* CPR facility. Mattress will deflate in less than 20 seconds
* Transport facility allows the mattress to be fully inflated while transporting mattress system
* Clip on tubes to prevent mattress from being disconnected from pump

Factors To Consider

All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

It is advisable that a health professional be consulted when considering a suitable pressure care product.

Disclaimer

Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre (ILC) is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILC for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.